E17
Constructa
Excessive Water Pressure / Fast Fill Error
Dishwasher fills too quickly or indicates high inlet pressure, E17 displayed.
Advertisements
Possible Causes
Household water pressure too high,Faulty or missing pressure reducer,Inlet valve not regulating correctly,Flow meter misreading high flow
How to Fix / Troubleshooting
Safety first: Turn off water and power before modifying plumbing.
- 1. Check tap pressure: If water blasts from the kitchen tap, your pressure may be above the dishwasher's recommended limit.
- 2. Install or adjust pressure reducer: Fit a pressure-reducing valve on the dishwasher feed line if not already present, or adjust an existing one to around 2–4 bar as recommended.
- 3. Partially close tap (temporary): As a short-term measure, slightly close the supply tap to reduce flow, then test the dishwasher.
- 4. Inspect inlet valve: If E17 persists at normal pressure, the inlet valve may not be closing correctly and should be checked.
When to call a technician: For permanent pressure regulation or valve replacement, professional service is advisable.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Pressure Reducing Valve / Water Inlet Valve
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements