Dacor
User Interface (UI) Failure
Control panel buttons are unresponsive or only some keys work intermittently.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed Dacor UI control board, Moisture intrusion into control panel, Loose ribbon cable, Worn touchpad contacts
How to Fix / Troubleshooting
Safety first: Disconnect power before removing the control panel.
- Power reset: Turn off the breaker for 5 minutes, then restore power to rule out a temporary software lockup.
- Inspect for moisture: Remove the inner door panel and check the UI board for signs of condensation or corrosion. Dry carefully and correct any gasket issues.
- Check ribbon cable: Ensure the ribbon cable between the UI and main board is fully seated and not damaged.
- Replace UI board: If specific buttons consistently fail and the board shows no visible damage, replace the Dacor user interface control.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Dacor User Interface Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements