E16
Dacor Inlet Valve Stuck Open / Overfill Protection

Dishwasher displays E16; water may continuously enter the tub or overfill even when the unit is off.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Mechanically stuck-open Dacor inlet valve, Debris lodged in valve seat, Control board energizing valve at wrong time, Faulty overfill protection circuit

How to Fix / Troubleshooting

Safety first: Immediately close the water supply valve and disconnect power to prevent flooding.

  • Confirm valve behavior: With power off and water on, check if water still flows into the dishwasher. If so, the inlet valve is stuck open mechanically.
  • Replace the inlet valve: Access the bottom front of the dishwasher, disconnect the water line and wiring, and remove the Dacor inlet valve. Install a new valve with the correct orientation and gasket.
  • Inspect for debris: Check the supply line for sediment that could re-contaminate the new valve. Flush the line before reconnecting.
  • Check control output (if valve closes with power off): If water only flows when power is on, the control board may be energizing the valve incorrectly. This requires electrical diagnosis and likely board replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Dacor Water Inlet Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements