E17
De Dietrich High Water Pressure / Overfill Detection

Dishwasher displays E17; rapid fill or overfill detected

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Excessive mains water pressure, Faulty flow meter reading too low, Sticking inlet valve, Blocked pressure chamber

How to Fix / Troubleshooting

Safety first: Unplug the appliance and close the water tap.

  • Check water pressure: If you suspect very high mains pressure, install a pressure reducer on the supply line or partially close the tap to reduce flow.
  • Inspect flow meter and pressure system: Clean the side water matrix and pressure chamber as described for E14 and E2 to ensure accurate level and flow measurement.
  • Test inlet valve: Verify that the inlet valve closes promptly when power is removed. If it dribbles or continues to flow, replace the valve.
  • Reset and test: After adjustments, run a test cycle. Persistent E17 may indicate a control board calibration issue requiring professional service.
Advertisements

Repair Difficulty

Medium 3/5

Required Part