E2
Fisher & Paykel Drain Timeout

Dishwasher displays E2; water remains in tub after cycle, or unit stops with error during drain.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Clogged drain hose, Blocked air gap or sink connection, Failed drain pump, Obstruction in pump impeller

How to Fix / Troubleshooting

Safety first: Disconnect power before working on drainage.

  • Clean filters and sump: Remove and clean all filters. Check the sump for debris blocking the drain pump inlet.
  • Check external plumbing: Inspect the air gap (if fitted), sink trap, and garbage disposer inlet for clogs. Clear any blockages.
  • Flush drain hose: Disconnect the drain hose from the sink and flush with water to ensure it is clear.

If the pump hums but does not move water, or is silent, the drain pump may need replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Drain Pump
Check Price on Amazon