E19
Gaggenau
Water Softener / Regeneration Valve Fault
Dishwasher shows E19, often related to the water softener or regeneration system.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective regeneration valve, blocked softener channels, wiring fault to softener valve, control board output failure
How to Fix / Troubleshooting
Safety: Disconnect power and water.
Steps:
- Check salt level: Ensure the salt reservoir is filled with dishwasher salt and cap is properly closed.
- Access softener valve: The regeneration valve is usually mounted on or near the water softener tank/heat exchanger. Remove the side panel to locate it.
- Inspect wiring: Verify the connector to the valve is secure and wires are intact.
- Test valve coil: Measure resistance across the valve coil. An open circuit indicates a failed valve that must be replaced.
- Replace regeneration valve: Install the correct Gaggenau valve and check for leaks.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Regeneration Valve (Water Softener Valve)
Check Price on Amazon
We may earn a commission from links on this page.