F3
GE Café Temperature Sensor / Thermistor Error

Dishwasher displays F3; unit may not heat or may terminate cycles prematurely.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted thermistor in sump, Damaged sensor wiring harness, Faulty main control board interpreting sensor signal incorrectly

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker before accessing the sump or wiring.

  • Locate thermistor: Remove the lower rack and filters. The thermistor is typically mounted in the sump wall or base on GE Café models.
  • Inspect wiring: From underneath, locate the thermistor connector and harness. Check for pinched, cut, or corroded wires. Repair as needed.
  • Test thermistor: Disconnect the sensor and measure resistance at room temperature. Compare to GE specifications. If reading is open, shorted, or far out of range, replace the thermistor.
  • Control board check: If a new thermistor does not clear F3, the main control board may be faulty and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

GE Café Dishwasher Thermistor
Check Price on Amazon

We may earn a commission from links on this page.