Hobart
Poor Drying / Inadequate Rinse Aid or Final Rinse Temperature
Dishes are wet or not drying properly at the end of the Hobart dishwasher cycle.
Advertisements
Possible Causes
Rinse aid not dispensing, Final rinse temperature too low, Excessive rinse water left on wares due to low pressure, Improper rack loading preventing drainage
How to Fix / Troubleshooting
Safety first: Allow the machine and wares to cool before inspection.
- Check rinse aid level: Ensure the rinse aid container is filled and the pickup tube is submerged. Prime the rinse aid pump if necessary.
- Verify rinse temperature: Observe the final rinse temperature on the display or gauge. It should meet Hobart specifications for your model. If low, troubleshoot the booster heater and supply temperature.
- Inspect rinse nozzles: Clean final rinse nozzles to ensure even coverage and proper sheeting of water off the wares.
- Improve rack loading: Load dishes at an angle to promote drainage and avoid nesting items that trap water.
- Adjust chemical dosing: Work with your chemical supplier to optimize rinse aid dosage for your water hardness and ware type.