E13
Hobart Low Rinse Pressure / Flow Fault

Hobart dishwasher shows E13; low rinse pressure or flow detected during final rinse.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Rinse line strainer clogged, Rinse solenoid valve partially blocked, Building water pressure too low, Rinse pressure switch or flow sensor fault

How to Fix / Troubleshooting

Safety first: Disconnect power and close the rinse water supply before opening any plumbing connections.

  • Check building pressure: Confirm that the incoming water pressure meets Hobart specifications. Low building pressure can cause E13.
  • Clean strainers: Locate and remove the rinse line strainer or filter. Rinse thoroughly to remove debris and scale.
  • Inspect rinse valve: Remove the rinse solenoid valve inlet screen and clean any sediment. If the valve is noisy or fails to open fully, replacement may be required.
  • Verify rinse nozzles: Remove and clean final rinse nozzles or jets on the rinse arm. Blocked nozzles reduce flow and pressure.
  • Sensor check: If equipped with a rinse pressure switch or flow meter, inspect tubing and wiring. Replace the sensor if it is blocked or electrically faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Rinse Solenoid Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements