E17
Hobart Vent Fan / Steam Condenser Fault

Hobart dishwasher shows E17; exhaust or venting fault, often on high-temperature models with vent fans.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Vent fan motor failure, Blocked vent duct, Condenser coil clogged with grease or scale, Faulty vent fan relay

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the vent or fan assembly. Beware of sharp metal edges.

  • Inspect vent outlet: Check that the external vent or hood is not blocked by debris, grease buildup, or construction materials.
  • Clean condenser/duct: Remove accessible panels to reach the steam condenser or vent duct. Clean accumulated grease and scale with appropriate cleaners.
  • Check fan operation: Restore power and start a cycle. Listen for the vent fan. If it does not run, test for power at the fan terminals (qualified personnel only).
  • Replace fan if needed: A seized or noisy fan motor should be replaced with a Hobart-compatible vent fan assembly.
  • Control check: If the fan is good but not energized, the fan relay or control board output may be faulty and require technician service.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Vent Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements