E11
Hoonved Rinse Aid Dosing System Fault

E11 error; rinse aid is not being dispensed and glasses may show spotting or poor drying.

Advertisements

Possible Causes

Empty rinse aid container, Blocked rinse aid suction filter, Defective rinse aid dosing pump, Faulty control signal to dosing pump

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing internal components. Use gloves when handling rinse aid.

  • Verify rinse aid level: Check the external or built-in rinse aid container and refill if empty.
  • Clean suction filter: Remove the suction tube from the container and clean any small filter or check valve at the end. Rinse under warm water to remove residue.
  • Inspect tubing: Follow the tubing from the pump to the injection point. Straighten any kinks and replace brittle or cracked tubing.
  • Test pump: In service/test mode (if available), trigger a rinse aid dose and listen for the pump. If silent or only humming, the pump may be seized and require replacement.
  • Check electrical connections: Ensure the pump connectors are firmly attached to the control board and that there are no burnt contacts.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Rinse Aid Dosing Pump
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements