E3
Hoonved
Heating Timeout / No Temperature Rise
Machine fills but does not heat; E3 appears on the display and the cycle time extends indefinitely.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed tank heating element, Failed boiler heating element (on models with separate boiler), Faulty temperature probe (NTC) in tank or boiler, Defective heating relay or triac on main control board
How to Fix / Troubleshooting
Safety first: Disconnect power and allow the machine to cool completely before touching internal components. Water and metal parts may be very hot.
- Verify power supply: Confirm that the correct three-phase or single-phase supply is present and that external breakers or fuses have not tripped. Hoonved dishwashers often require a dedicated high-amperage circuit.
- Check for scale on heating elements: Remove access panels to inspect the tank and boiler heating elements. Heavy limescale can cause overheating and failure. If elements are heavily scaled, descaling or replacement is recommended.
- Test heating elements: With a multimeter (and power disconnected), measure resistance across the element terminals. An open circuit indicates a failed element. Compare readings with service manual values if available.
- Inspect temperature probes: Locate the NTC probe in the wash tank and/or boiler. Ensure it is firmly seated and wiring is intact. A broken or shorted probe can cause the control to disable heating.
- Check control board outputs: If elements and probes test correctly, the heating relay or triac on the main PCB may be defective. Visual signs include burnt tracks or relays. Board-level repair should be done by a qualified technician.
- After repair: Reassemble, restore power, clear the E3 error, and run a full cycle while monitoring temperature rise on the display.