E7
Hoonved Boiler Temperature Probe Fault

E7 appears and the dishwasher may not complete the rinse; boiler temperature reading may be unrealistic (very high or very low).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted boiler NTC probe, Loose or corroded probe connector, Damaged wiring harness to boiler, Faulty control board boiler sensor input

How to Fix / Troubleshooting

Safety first: Turn off power and allow the boiler to cool before touching any boiler components.

  • Locate boiler NTC: On Hoonved dishwashers, the boiler NTC is usually mounted on the boiler shell or inserted into a thermowell. Remove the cover to access it.
  • Inspect connector: Disconnect and reconnect the probe plug several times to clean light oxidation. Ensure the connector is tight.
  • Measure resistance: With the probe disconnected, measure resistance at ambient temperature and compare with specification. Replace the probe if readings are out of range or unstable when gently moved.
  • Check cable routing: Ensure the cable is not routed near high-voltage lines or hot surfaces that could damage insulation.
  • Control board diagnosis: If a known-good probe still triggers E7, the main PCB may be faulty. Replacement is recommended via an authorized Hoonved service center.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Boiler NTC Temperature Probe
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements