E8
Hoonved
Water Level Sensor / Pressure Switch Fault
E8 error; machine may not fill correctly or may overfill, sometimes accompanied by unusual water levels in the tank.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked pressure switch hose, Defective pressure switch, Faulty electronic level sensor or probe, Wiring fault between level device and control board
How to Fix / Troubleshooting
Safety first: Disconnect power and close the water supply before opening panels.
- Locate level device: Depending on the Hoonved model, water level is controlled by a mechanical pressure switch, an electronic pressure sensor, or stainless-steel level probes in the tank.
- Clean pressure hose: If a pressure switch is used, remove the small rubber hose from the switch and the tank connection. Blow through it to clear grease or scale. Replace if cracked or soft.
- Check pressure switch operation: Gently blow into the switch port and listen for clicks. Use a multimeter to verify contact change. Replace if it does not switch reliably.
- Clean level probes: For probe systems, remove the probes from the tank and clean them with a non-abrasive pad to remove scale and detergent film. Ensure insulators are intact.
- Inspect wiring: Verify that connectors are tight and wires are not damaged or corroded.
- Test machine: Reassemble, restore power, and run a fill cycle while monitoring water level. If E8 persists, the control board input may be defective.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Level Pressure Switch
Check Price on Amazon