Hoonved
Overfilling / Level Control Failure
Machine overfills and water level is visibly above normal, sometimes spilling into the base.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck water inlet valve, Blocked or disconnected pressure switch hose, Faulty pressure switch contacts, Shorted level probe to ground
How to Fix / Troubleshooting
Safety first: Immediately disconnect power and close the water supply if overfilling occurs.
- Check inlet valve: If water continues to enter with power off, the valve is mechanically stuck open and must be replaced.
- Inspect pressure hose: Ensure the hose from the tank to the pressure switch is connected and not blocked.
- Test pressure switch: Replace if it does not change state at the correct water level.
- Clean level probes: Remove and clean probes to eliminate conductive bridges of scale or detergent.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Water Inlet Solenoid Valve
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements