E8
Iberna Circulation Pump / Wash Motor Error

Dishwasher shows E8 and may have weak spray pressure or incomplete washing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed circulation pump motor, Jammed impeller, Seized motor bearings, Faulty motor capacitor (if fitted)

How to Fix / Troubleshooting

Safety first: Unplug the dishwasher and turn off the water supply. Expect some residual water in the sump.

  • Listen for motor operation: Start a cycle and listen. A humming noise without water movement suggests a jammed or failed circulation pump.
  • Check for obstructions: Remove lower spray arm and sump filter. Look into the sump for broken glass, bones, or other debris that could jam the impeller. Remove carefully.
  • Access circulation pump: Lay the dishwasher on its back and remove the base panel. Locate the circulation pump attached to the sump. Inspect for leaks or burn marks.
  • Test impeller and bearings: Try turning the impeller by hand. It should rotate smoothly. If stiff or seized, replace the circulation pump assembly.
  • Motor capacitor (if present): Some Iberna pumps use a start capacitor. Check for bulging or leakage and test capacitance. Replace if out of spec.

Because the circulation pump is central to wash performance, replacement is often the most effective repair when E8 occurs.