AL02
Indesit
Water Inlet / Flow Meter Fault
Dishwasher displays AL02 and does not fill correctly, often stopping early in the cycle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked or failed flow meter in inlet assembly, Restricted inlet filter, Faulty water inlet valve, Wiring fault to flow sensor
How to Fix / Troubleshooting
Safety: Turn off water and disconnect power before removing hoses or panels.
Check inlet filters and pressure:
- Clean the mesh filters at the tap and valve ends of the inlet hose.
- Confirm good water pressure at the tap by running water into a bucket.
Flow meter inspection:
- On many Indesit models, the flow meter is integrated into the inlet valve or side water matrix.
- Remove the side panel and locate the small sensor with wires attached to the water path.
- Check the connector is secure and free of corrosion.
Action:
- If the flow meter is physically damaged or the wiring is broken, replace the inlet/flow meter assembly.
- If water flow is weak due to limescale in the water matrix, consider replacing the matrix or descaling if possible.