E10
Jet Tech
Booster Heater Fault
Dishwasher displays E10; booster heater does not reach sanitizing temperature
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open booster heating element, Tripped high-limit thermostat on booster, Faulty booster temperature probe, Defective booster contactor or relay
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker and allow the booster to cool completely. Booster heaters operate at high temperatures and voltages.
- 1. Check high-limit reset: Locate the booster heater (often a separate stainless steel tank). Find the manual reset high-limit thermostat on the booster shell and press the reset button if tripped.
- 2. Inspect wiring and contactor: Look for burned wires, loose terminals, or a stuck contactor supplying power to the booster element.
- 3. Test booster element: With power off and wires removed, measure resistance across the booster element terminals. An open reading indicates a failed element.
- 4. Verify booster NTC: Measure the resistance of the booster temperature sensor and compare to Jet Tech specifications. Replace if out of range.
- 5. Control and relay check: If all components test good, the control board or booster relay may not be energizing the heater.
- When to call a technician: Due to the high power of booster heaters, replacement of elements, contactors, or controls should be done by a licensed technician.