E17
Jet Tech
Level Control / Siphoning Fault
Dishwasher shows E17; machine fills and drains repeatedly without completing cycle
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Improper drain hose installation causing siphoning, Faulty water level pressure switch, Blocked pressure chamber, Control board level logic error
How to Fix / Troubleshooting
Safety first: Turn off power and water before adjusting plumbing connections.
- 1. Check drain hose height: Ensure the drain hose rises to the manufacturer-specified height above the floor before connecting to the drain. A hose that is too low can cause siphoning.
- 2. Inspect air break: If an air gap or break is installed, confirm it is not bypassed or blocked.
- 3. Clean pressure chamber: Locate the pressure chamber or tube connected to the level switch. Remove and flush it to clear grease or scale that may trap air.
- 4. Test pressure switch: With a multimeter, verify that the switch changes state at the correct water level (requires service specs).
- When to call a technician: If the control board misinterprets level signals or the pressure switch needs calibration, professional service is recommended.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Level Pressure Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements