E13
Meiko
Communication Bus Fault
E13 displayed; communication error between main control board and user interface or peripheral module.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose data cable between boards, Damaged communication harness, Faulty user interface PCB, Defective main control PCB
How to Fix / Troubleshooting
Safety first: Disconnect the dishwasher from mains power before opening the control compartment.
- Inspect communication cables: Locate the low-voltage data cables (often flat ribbon or multi-core) between the main control board and the display or peripheral modules. Ensure all connectors are fully seated.
- Check for damage: Look for pinched, cut, or burned cables, especially where they pass through metal panels. Replace any damaged harnesses.
- Clean connectors: Use contact cleaner on oxidized pins and reseat connectors firmly. Ensure correct orientation of keyed plugs.
- Module substitution: If available, swap the user interface PCB with a known-good unit to determine whether the fault follows the module.
- Main PCB assessment: If cabling and interface are good, the main control board may have a failed communication driver. Replacement should be performed by a Meiko-trained technician.
- Power up and test: After reassembly, restore power and check if E13 clears and the display responds normally.