Meiko
Rinse Arm Rotation / Flow Restriction
Rinse arms do not rotate properly; spray pattern is weak or uneven.
Advertisements
Possible Causes
Clogged rinse nozzles, Worn rinse arm bearings, Low rinse pressure, Debris in rinse arm hub
How to Fix / Troubleshooting
Safety first: Turn off power and allow the machine to cool before removing rinse arms.
- Remove and clean rinse arms: Take out upper and lower rinse arms. Clean all nozzles and internal channels with a brush and descaling solution if needed.
- Inspect bearings and bushings: Check the arm hubs for wear. Replace worn bushings or complete arms if they wobble or bind.
- Check rinse pressure: Verify that rinse pressure meets Meiko specifications. If low, inspect the booster pump and filters.
- Reinstall and test: Ensure arms spin freely by hand. Run a cycle and observe rotation through the door (if possible).
Advertisements
Repair Difficulty
Easy
2/5