Possible Causes

Drain hose installed without proper air break, Blocked drain line, Faulty non-return valve, Incorrect drain height

How to Fix / Troubleshooting

Safety first: Turn off power before working on the drain system.

  • Check drain hose routing: Ensure the hose has a proper high loop or air break as specified by Meiko to prevent backflow from the building drain.
  • Clean drain line: Disconnect and flush the drain hose to remove grease and debris. Clean any external air gap or trap.
  • Inspect non-return valve: Locate the check valve near the drain pump outlet. Remove and clean or replace if it does not close properly.
  • Verify drain height: Confirm that the building drain connection is at the correct height relative to the machine outlet to allow gravity drainage.