Meiko
Incomplete Drain / Backflow
Water remains in the tank overnight when it should have drained completely.
Advertisements
Possible Causes
Drain hose installed without proper air break, Blocked drain line, Faulty non-return valve, Incorrect drain height
How to Fix / Troubleshooting
Safety first: Turn off power before working on the drain system.
- Check drain hose routing: Ensure the hose has a proper high loop or air break as specified by Meiko to prevent backflow from the building drain.
- Clean drain line: Disconnect and flush the drain hose to remove grease and debris. Clean any external air gap or trap.
- Inspect non-return valve: Locate the check valve near the drain pump outlet. Remove and clean or replace if it does not close properly.
- Verify drain height: Confirm that the building drain connection is at the correct height relative to the machine outlet to allow gravity drainage.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Drain Non-Return Valve
Check Price on Amazon