E25
Mora
Drain Pump Impeller Blocked / Cover Obstructed
Dishwasher shows E25; drain pump may run but water drains slowly or not at all.
Advertisements
Possible Causes
Foreign object under pump cover, Blocked pump impeller, Misfitted pump cover, Debris in sump outlet
How to Fix / Troubleshooting
Safety first: Disconnect mains power before reaching into the sump.
- Remove filters: Take out the coarse and fine filters to access the sump area.
- Access pump cover: In many Mora models, the drain pump cover is accessible from inside the tub via a small plastic cover. Twist and remove it.
- Check for obstructions: Inspect the impeller area for glass, bones, or other debris. Remove carefully.
- Verify cover fit: Ensure the pump cover is reinstalled correctly and fully locked, as an incorrect fit can cause E25.
- Test drain: Restore power and run a drain or cancel program to confirm proper operation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Drain Pump Cover and Impeller
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements