Rosières Door Seal / Venting Issue

Condensation or steam escaping from top of door, causing damp worktop

Advertisements

Possible Causes

Deformed upper door seal, Blocked or stuck vent flap, Excessive steam due to very hot inlet water, Incorrect installation depth

How to Fix / Troubleshooting

Safety first: Allow the dishwasher to cool before touching the door area.

  • Inspect upper seal: Check the top door gasket for gaps or deformation. Replace if not sealing evenly.
  • Check vent: On models with a door vent, ensure the vent grille is not blocked and the flap can open/close freely.
  • Installation depth: Verify that the dishwasher is flush with the cabinet front as per Rosières guidelines; if recessed too far, steam may escape incorrectly.
  • Water temperature: Ensure inlet water is not excessively hot (above manufacturer recommendation).
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Gasket / Vent Assembly
Check Price on Amazon

We may earn a commission from links on this page.