E14
Sharp Flow Meter / Water Intake Measurement Fault

Dishwasher displays E14 and may not fill correctly; sometimes fills only partially or not at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty flow meter in AquaStop hose, Blocked flow meter turbine, Loose connector to flow sensor, Control board counting error

How to Fix / Troubleshooting

Safety first: Disconnect power and close the water tap before removing hoses.

  • Inspect AquaStop hose: Check the Sharp AquaStop inlet hose for kinks or crushing that could prevent the flow meter turbine from spinning.
  • Clean inlet filter: Remove and clean the mesh filter at the tap end to ensure proper water flow.
  • Check wiring: Follow the cable from the AquaStop/flow meter to the control board and ensure the connector is secure.
  • Test fill: Restore power and run a quick cycle. If E14 returns and filling is abnormal, the flow meter may be defective.
  • Replace AquaStop/flow meter: Install a new Sharp AquaStop hose with integrated flow meter if required.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

AquaStop Inlet Hose with Flow Meter
Check Price on Amazon