E01
Siemens Main Control Module Failure

Dishwasher will not start; display shows E01 shortly after pressing Start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective power module (control board), Burnt relay on control board, Internal short on control PCB, Overvoltage damage to electronics

How to Fix / Troubleshooting

Safety first: Disconnect the dishwasher from mains power by switching off the circuit breaker or unplugging it. Do not work on live circuits.

E01 on Siemens dishwashers typically indicates a failure of the main power module or control electronics.

  • Step 1 – Power reset:
    • Turn off the breaker for 5–10 minutes.
    • Restore power and try to start a short program.
    • If E01 returns immediately, proceed to inspection.
  • Step 2 – Check incoming power:
    • Verify the wall outlet or junction box has correct voltage using a multimeter (only if you are trained to do so).
    • Inspect the power cord and terminal block for burn marks or loose connections.
  • Step 3 – Access the control module:
    • Remove the outer door panel (usually Torx screws along the inner edge of the door).
    • Locate the power module (often in a plastic housing at the bottom right or behind the kick plate, depending on model).
    • Check for visible damage: burnt spots, melted connectors, or a burnt smell.
  • Step 4 – Connector check:
    • Reseat all wiring harness plugs to the control module firmly.
    • Inspect the harness for pinched or damaged wires, especially where the door opens and closes.
  • Step 5 – Replacement:
    • If the board is visibly damaged or E01 persists after reseating connectors, the power module is likely defective.
    • Order the exact Siemens power module by model and E-number (printed on the door frame).
    • Transfer connectors one by one from the old board to the new board to avoid miswiring.

Warning: If you are not experienced with mains-voltage electronics, have a qualified technician replace the control module.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Power Module (Main Control Board)
Check Price on Amazon

We may earn a commission from links on this page.