E04
Siemens Water Distribution / Spray Arm Control Fault

Dishwasher stops and displays E04; sometimes dishes are not rinsed properly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty diverter valve in sump, Blocked spray arms, Clogged water channels in heat exchanger, Defective circulation pump pressure switch

How to Fix / Troubleshooting

Safety first: Disconnect power and close the water tap before internal inspection.

E04 often relates to incorrect water distribution or a diverter valve issue.

  • Step 1 – Clean spray arms:
    • Remove upper and lower spray arms.
    • Rinse under running water and use a toothpick to clear blocked jets.
    • Ensure the arms rotate freely when reinstalled.
  • Step 2 – Check filters and sump:
    • Remove the bottom filter assembly and coarse filter.
    • Clean all filters thoroughly with warm soapy water.
    • Inspect the sump for foreign objects (glass, bones, labels) that could block the diverter or pump.
  • Step 3 – Diverter valve inspection:
    • Access the sump from below (tilt the dishwasher back after removing the base cover; protect the floor).
    • Locate the diverter valve motor on the circulation pump housing.
    • Check for broken wires or a jammed diverter mechanism.
  • Step 4 – Functional test:
    • With the machine reassembled, run a short cycle and listen for the diverter clicking or changing spray zones.
    • If no change is heard and E04 returns, the diverter valve or its motor is likely defective.
  • Step 5 – Replacement:
    • Replace the diverter valve assembly or the complete circulation pump module (depending on model design).

If you are not comfortable accessing the sump from below, contact a professional technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Diverter Valve (Spray Arm Distributor)
Check Price on Amazon