E09
Siemens Heating Circuit Failure (Flow Heater / Heat Pump)

Dishwasher completes cycle but dishes are cold and wet; E09 is displayed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Burnt-out flow-through heater, Failed heat pump assembly, Loose or burnt heater connectors, Faulty heater relay on control board

How to Fix / Troubleshooting

Safety first: Disconnect power and allow the machine to cool before working near the heater.

E09 is a common Siemens code for a failed heating element in the circulation pump/heat pump assembly.

  • Step 1 – Confirm symptom:
    • Run a hot program and open the door immediately after it ends (careful of steam).
    • If the interior and dishes are cold and E09 appears, the heater is not working.
  • Step 2 – Access heater/heat pump:
    • Remove the dishwasher from the cabinet and lay it on its back (protect the floor).
    • Remove the bottom base cover to access the circulation pump/heat pump assembly.
  • Step 3 – Visual inspection:
    • Check the heater terminals and wiring for burning or loose connections.
    • Inspect for leaks around the pump that may have damaged the heater.
  • Step 4 – Resistance test (for trained users):
    • Disconnect the heater connectors.
    • Measure resistance across the heater; a typical value is 15–30 Ω (check service data).
    • If open circuit, the heater is defective.
  • Step 5 – Replacement:
    • On many Siemens models, the heater is integrated with the circulation pump (heat pump).
    • Replace the complete heat pump assembly with the correct Siemens part.
    • Ensure all hose clamps and seals are correctly fitted to prevent leaks.

If the heater tests good, the fault may be on the control board heater relay, which usually requires board replacement.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Heat Pump / Flow-Through Heater Assembly