E16
Siemens
Inlet Valve / AquaStop Stuck Open
Dishwasher overfills or continuously takes in water and shows E16.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective AquaStop inlet valve, Debris preventing valve from closing, Faulty control signal keeping valve energized, Stuck relay on control board
How to Fix / Troubleshooting
Safety first: Immediately close the water tap and disconnect power to prevent flooding.
E16 indicates uncontrolled water intake.
- Step 1 – Check AquaStop hose:
- Inspect the AquaStop inlet hose for damage.
- If water continues to flow into the dishwasher when power is off but tap is open, the valve is mechanically stuck open.
- Step 2 – Replace AquaStop:
- Turn off the water tap.
- Disconnect the AquaStop hose from the tap and dishwasher.
- Install a new Siemens AquaStop hose of the correct type.
- Step 3 – Control check (if valve only opens with power):
- If the valve only misbehaves when powered, the control board may be energizing it incorrectly.
- Inspect the control board for a stuck relay; replace the board if necessary.
Always test for proper filling and shutoff after replacing the AquaStop to ensure no risk of flooding.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
AquaStop Inlet Valve Hose
Check Price on Amazon
We may earn a commission from links on this page.