E17
Siemens Overfilling / High Water Pressure Fault

Dishwasher shows E17; filling stops early or water hammer noises are heard.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Household water pressure too high, Faulty flow meter reading excessive flow, Sticking inlet valve, Incorrect installation of inlet hose

How to Fix / Troubleshooting

Safety first: Disconnect power and close the water tap before adjustments.

E17 is related to overfilling or too rapid filling.

  • Step 1 – Check water pressure:
    • If you have very high mains pressure, consider installing a pressure reducer on the supply line.
  • Step 2 – Inlet hose and valve:
    • Inspect the AquaStop hose and valve for sticking or debris.
    • Clean the inlet filter screen.
  • Step 3 – Flow meter:
    • As with E14, inspect and, if necessary, replace the flow meter if it is miscounting pulses.
  • Step 4 – Test:
    • After any changes, run a test cycle and monitor filling behavior.

If E17 persists despite normal water pressure and a clean inlet system, the control board may be misinterpreting flow data and require replacement.