E24
Siemens Drainage Problem / Drain Hose Blockage

Dishwasher shows E24; water may not drain and you may hear the drain pump running.

Advertisements

Possible Causes

Kinked or blocked drain hose, Blocked sink trap connection, Incorrect drain hose installation height, Partial blockage in sump or pump inlet

How to Fix / Troubleshooting

Safety first: Disconnect power before working on hoses or plumbing.

E24 is a common Siemens code for drainage issues.

  • Step 1 – Check filters and sump:
    • Clean the filter assembly and sump as for E22.
  • Step 2 – Inspect drain hose:
    • Follow the drain hose from the dishwasher to the sink or standpipe.
    • Straighten any kinks or sharp bends.
    • Detach the hose from the sink trap and check for blockages; clean if necessary.
  • Step 3 – Installation height:
    • Ensure the drain hose is installed at the correct height as per Siemens instructions (usually 40–100 cm above floor).
  • Step 4 – Pump check:
    • If the hose and sink are clear but E24 persists, inspect the drain pump as for E23.

After clearing blockages, run a short program to verify that the dishwasher drains completely and E24 is resolved.