E14
Summit Water Level / Flow Meter Calibration Error

Dishwasher shows E14; unit may stop filling or may fill erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective flow meter, Incorrect installation height of drain hose causing siphoning, Air in water line affecting flow readings, Faulty main control board calibration

How to Fix / Troubleshooting

Safety first: Disconnect power and water before adjustments.

  • Verify drain hose installation: Ensure the drain hose is installed with a proper high loop or air gap as specified by Summit. A hose that is too low can cause siphoning and confuse water level detection.
  • Bleed air from line: Turn off water, disconnect the inlet hose, then reconnect and slowly open the valve to reduce trapped air.
  • Check flow meter: Inspect and test the flow meter for proper operation. Replace if readings are inconsistent.
  • Control reset: Perform a hard reset by turning off the breaker for several minutes. If E14 persists, the main control board may require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Meter
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements