E25
V-ZUG Drain Pump Impeller Blocked / Cover Misfitted

Dishwasher displays E25, often with loud noises from the drain area or no draining.

Advertisements

Possible Causes

Pump cover not seated correctly, Foreign object in pump impeller, Broken glass or bone fragments in pump, Pump housing damaged

How to Fix / Troubleshooting

Safety first: Unplug the appliance. Water may be hot; use gloves.

  • Access pump cover: Remove the filters and locate the small pump cover in the sump (often with a twist-lock). Remove it according to the user manual.
  • Inspect impeller: Look for and remove any foreign objects around the impeller. Rotate the impeller gently with a finger or non-metallic tool to ensure it moves freely.
  • Reinstall cover: Refit the pump cover securely, ensuring it locks into place. An incorrectly fitted cover can cause E25.
  • Test drain: Run a drain or short program and listen for normal pump operation.
  • If E25 persists: The pump housing or impeller may be damaged and require replacement by a technician.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Drain Pump Cover / Impeller
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements