E25
V-ZUG
Drain Pump Impeller Blocked / Cover Misfitted
Dishwasher displays E25, often with loud noises from the drain area or no draining.
Advertisements
Possible Causes
Pump cover not seated correctly, Foreign object in pump impeller, Broken glass or bone fragments in pump, Pump housing damaged
How to Fix / Troubleshooting
Safety first: Unplug the appliance. Water may be hot; use gloves.
- Access pump cover: Remove the filters and locate the small pump cover in the sump (often with a twist-lock). Remove it according to the user manual.
- Inspect impeller: Look for and remove any foreign objects around the impeller. Rotate the impeller gently with a finger or non-metallic tool to ensure it moves freely.
- Reinstall cover: Refit the pump cover securely, ensuring it locks into place. An incorrectly fitted cover can cause E25.
- Test drain: Run a drain or short program and listen for normal pump operation.
- If E25 persists: The pump housing or impeller may be damaged and require replacement by a technician.