F5
V-ZUG
Spray Arm / Circulation Fault
Dishwasher shows F5 and may stop with poor spray performance.
Advertisements
Possible Causes
Spray arms clogged, Circulation pump partially blocked, Low water level due to inlet issues, Diverter valve malfunction
How to Fix / Troubleshooting
Safety first: Turn off power before removing spray arms.
- Clean spray arms: Remove upper and lower spray arms. Rinse under running water and use a toothpick to clear blocked jets.
- Check for free rotation: Reinstall spray arms and spin them by hand to ensure they rotate freely and do not hit dishes.
- Clean filters: Ensure filters and sump are clean to allow full pump flow.
- Run a hot cycle: Use a dishwasher cleaner to remove internal grease that can affect circulation.
- Persistent F5: The circulation pump or diverter valve may be failing and should be inspected by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Spray Arms / Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.