F6
V-ZUG Water Intake / Flow Fault

Dishwasher displays F6 and may not fill or may abort early.

Advertisements

Possible Causes

Water tap closed, Inlet hose kinked, Inlet filter clogged, Flow meter not detecting water

How to Fix / Troubleshooting

Safety first: Switch off power and close the water tap.

  • Open water tap fully: Confirm the supply valve is fully open.
  • Inspect inlet hose: Ensure the hose is not kinked or crushed behind the appliance.
  • Clean inlet filters: Remove and rinse the mesh filters in the hose and machine connection.
  • Test fill: Restore power and run a short program to see if filling is normal.
  • If F6 persists: The flow meter or inlet valve may be defective and require professional service.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Inlet Valve / Flow Meter
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements