E71
AEG NTC Sensor Open-Circuit

Dryer may not start heating; E71 displayed or logged; control detects NTC out of range (open circuit).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Disconnected NTC sensor, Broken NTC element, Broken wire in sensor harness

How to Fix / Troubleshooting

Safety first: Unplug the dryer.

  • 1. Inspect NTC plug: Access the NTC sensor and ensure its connector is fully seated.
  • 2. Check for broken wires: Gently tug each wire leading to the NTC; if any feel loose or stretch, the conductor may be broken inside the insulation.
  • 3. When to call a technician: Replace the NTC sensor and repair wiring as needed; this is typically a straightforward job for a professional.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

NTC Temperature Sensor
Check Price on Amazon