E80
AEG
Program Selector / User Interface Fault
Dryer display or selector behaves erratically; E80 or similar appears; wrong program may be detected.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty program selector switch, Dirty or oxidized selector contacts, Damaged user interface PCB, Loose ribbon cable between UI and main board
How to Fix / Troubleshooting
Safety first: Unplug the dryer before removing the control panel.
- 1. Check knob alignment: Ensure the program selector knob is not cracked and is correctly aligned with the shaft.
- 2. Inspect UI connections: Remove the control panel and check the ribbon cable and connectors between the user interface and main control board.
- 3. Clean contacts: If accessible, gently clean selector contacts with appropriate electronic contact cleaner (do not soak).
- 4. When to call a technician: If E80 persists, the selector or UI PCB may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface PCB
Check Price on Amazon