E8
Amana Overtemperature or High Exhaust Temperature Error

Dryer shows E8 and may overheat or shut down unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Restricted exhaust vent, Failed cycling thermostat, Stuck heater relay, Shorted heating element to ground

How to Fix / Troubleshooting

Safety first: Unplug the dryer and allow it to cool completely. For gas models, shut off gas supply.

  • Clean venting: Thoroughly clean the lint filter, internal ducts, blower housing, and external vent system to restore airflow.
  • Inspect thermostats: Access the heater housing and blower housing. Test the cycling thermostat and high-limit thermostat for proper continuity and operation.
  • Check heating element (electric): Test for shorts to ground and proper resistance. Replace if defective.
  • Control relay: If the heater remains on when it should be off, the control board’s heater relay may be stuck closed and the board will need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cycling Thermostat
Check Price on Amazon