F09
Ariston EEPROM / Software Configuration Error

Dryer will not start or behaves erratically, F09 displayed

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted firmware on control board, Incorrect configuration data, Power surge damage to memory

How to Fix / Troubleshooting

Safety first: Disconnect the dryer from mains before accessing internal components.

  • Power cycle: Unplug the dryer for at least 10 minutes to allow capacitors to discharge and the control to fully reset. Reconnect and test.
  • Check supply stability: Ensure the dryer is connected to a stable power source, not a loose extension lead or shared outlet that may cause voltage drops.
  • Factory reset (if available): Some Ariston models allow a service reset via a button combination (refer to service documentation). Only perform if you know the correct procedure.
  • Board replacement: If F09 persists, the control board’s memory is likely corrupted. Replacement of the main PCB is usually required and should be done by a qualified technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board (PCB)
Check Price on Amazon