H01
Ariston Heat Pump System Low Efficiency / Sensor Fault

Heat pump dryer shows H01 and does not start or stops early

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser or heat exchanger, Faulty heat pump temperature sensor, Insufficient airflow through heat pump module

How to Fix / Troubleshooting

Safety first: Unplug the dryer. Heat pump components can be sharp and may contain refrigerant; do not damage sealed parts.

  • Clean filters and condenser: Remove and clean the main lint filter and any secondary filters. Access the heat exchanger/condenser and clean thoroughly with a soft brush and vacuum.
  • Check ambient conditions: Ensure the dryer is installed in a room within the recommended temperature range; very cold rooms can trigger heat pump errors.
  • Inspect sensors and wiring: Locate the heat pump NTC sensors on the evaporator and condenser. Check connectors and wiring for damage and reseat them.
  • When to call a technician: If H01 persists after cleaning and checks, the heat pump circuit (compressor, sensors, or refrigerant charge) may be faulty and requires professional service.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Heat Pump Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements