H01
Ariston
Heat Pump System Low Efficiency / Sensor Fault
Heat pump dryer shows H01 and does not start or stops early
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser or heat exchanger, Faulty heat pump temperature sensor, Insufficient airflow through heat pump module
How to Fix / Troubleshooting
Safety first: Unplug the dryer. Heat pump components can be sharp and may contain refrigerant; do not damage sealed parts.
- Clean filters and condenser: Remove and clean the main lint filter and any secondary filters. Access the heat exchanger/condenser and clean thoroughly with a soft brush and vacuum.
- Check ambient conditions: Ensure the dryer is installed in a room within the recommended temperature range; very cold rooms can trigger heat pump errors.
- Inspect sensors and wiring: Locate the heat pump NTC sensors on the evaporator and condenser. Check connectors and wiring for damage and reseat them.
- When to call a technician: If H01 persists after cleaning and checks, the heat pump circuit (compressor, sensors, or refrigerant charge) may be faulty and requires professional service.