F14
Bauknecht
Heat Pump Temperature Sensor / Pressure Sensor Fault
Dryer shows F14 and does not heat properly, especially on heat pump models.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective heat pump NTC sensor, Faulty pressure sensor (if equipped), Wiring fault to sensor, Control board sensor input failure
How to Fix / Troubleshooting
Safety first: Disconnect mains power before opening panels.
- Access heat pump area:
- Remove side or rear panels as per service instructions.
- Locate NTC sensors attached to the heat pump circuit or heat exchanger.
- Check connections: Ensure all sensor plugs are firmly seated and wires are intact.
- Clean surroundings: Remove lint and dust from around sensors and the heat exchanger to ensure accurate temperature readings.
- Test sensors (if possible): Measure resistance and compare with service data; replace any sensor that is open, shorted, or out of range.
- If sensors test OK: The control board may misread sensor data and require replacement by a technician.
Note: Access to heat pump components can be complex; if unsure, seek professional service.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Heat Pump NTC Sensor
Check Price on Amazon