F14
Bauknecht Heat Pump Temperature Sensor / Pressure Sensor Fault

Dryer shows F14 and does not heat properly, especially on heat pump models.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective heat pump NTC sensor, Faulty pressure sensor (if equipped), Wiring fault to sensor, Control board sensor input failure

How to Fix / Troubleshooting

Safety first: Disconnect mains power before opening panels.

  • Access heat pump area:
    • Remove side or rear panels as per service instructions.
    • Locate NTC sensors attached to the heat pump circuit or heat exchanger.
  • Check connections: Ensure all sensor plugs are firmly seated and wires are intact.
  • Clean surroundings: Remove lint and dust from around sensors and the heat exchanger to ensure accurate temperature readings.
  • Test sensors (if possible): Measure resistance and compare with service data; replace any sensor that is open, shorted, or out of range.
  • If sensors test OK: The control board may misread sensor data and require replacement by a technician.

Note: Access to heat pump components can be complex; if unsure, seek professional service.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heat Pump NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.