F29
Bauknecht
Water Tank / Level Detection Fault
Dryer displays F29 and may not start or may stop with water-related issues.
Advertisements
Possible Causes
Full or incorrectly seated water tank, Faulty tank level switch, Blocked sensor in tank housing, Wiring fault to level sensor
How to Fix / Troubleshooting
Safety first: Disconnect power before removing internal covers. Removing and emptying the water tank can be done with power off and door closed.
- Empty and reseat tank:
- Remove the condensate water tank and empty it completely.
- Clean the tank and its contacts (if present) with a dry cloth.
- Reinsert firmly until it clicks into place.
- Check tank compartment: Inspect for lint or debris that may block the level sensor or float.
- Level switch: If accessible, test the tank level switch or sensor for proper operation and continuity.
- Wiring: Ensure the harness from the tank area to the control board is intact.
Note: Some models will not run if the tank is missing or not fully inserted, even if empty.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Tank Level Switch / Sensor
Check Price on Amazon