E16
Brandt
Door Locking System Error (Latch / Interlock)
Dryer shows E16, drum light may flash, cycle cannot be started
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Broken door latch hook, Misaligned door, Faulty door interlock switch, Damaged door lock wiring
How to Fix / Troubleshooting
Safety first: Unplug the dryer before removing the front panel or working near the door switch.
Steps:
- 1. Inspect door and latch: Check that the door closes evenly and the latch hook is not broken or bent. Replace the latch if damaged.
- 2. Check door interlock: Access the door lock assembly from inside the front panel. Ensure it is firmly mounted and the actuator from the door engages it fully.
- 3. Test the interlock: Disconnect the connector and test the switch contacts with a multimeter while operating the latch. Replace if it does not change state correctly.
- 4. Wiring harness: Inspect the harness from the door lock to the control board for damage or loose connectors.
Note: Do not bypass the door lock for operation; this is a serious safety hazard.