Brandt
Partial Heat Pump Performance Loss
Heat pump dryer runs but air inside drum is only lukewarm and drying is very slow
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty evaporator/condenser coils, Blocked airflow around heat pump module, Failing compressor, Faulty temperature sensor in heat pump circuit
How to Fix / Troubleshooting
Safety first: Unplug the dryer. Do not open the sealed refrigerant system.
Steps:
- 1. Clean all filters and heat exchangers: Ensure lint filter and any additional filters are clean. Vacuum dust from fixed heat pump coils carefully.
- 2. Ensure ventilation: Make sure there is adequate space around the dryer for air circulation.
- 3. Test with small load: Run a cycle with a small load and monitor temperature. If performance remains poor, a technician should check the compressor and sensors.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Heat Pump Compressor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements