Bush
Motor Start Failure / Capacitor Fault
Bush dryer drum light works and display is on, but pressing start only causes a click with no drum movement.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak or failed motor start capacitor, Stiff drum bearings, Faulty motor windings, Defective motor relay on PCB
How to Fix / Troubleshooting
Safety first: Unplug the dryer before accessing the motor or capacitor.
- Spin drum test: Try turning the drum by hand. If it is stiff, investigate bearings and supports. If it turns freely, suspect the capacitor or motor.
- Locate and inspect capacitor: Find the motor start capacitor near the motor. Look for bulging or leakage. Replace if visibly damaged.
- Test capacitor: Use a capacitance meter to verify its value against the rating printed on the case. Replace if out of tolerance.
- Check motor connections: Ensure the motor plug is secure and wires are intact.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Motor Start Capacitor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements