Bush Water Leak from Condenser or Sump

Bush dryer is leaking water onto the floor from the front or underneath.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser channel, Cracked or loose condensate hose, Overfilled or mis-seated water tank, Damaged sump or pump housing

How to Fix / Troubleshooting

Safety first: Unplug the dryer and mop up any spilled water to prevent slipping.

  • Check water tank: Remove, empty, and refit the water tank, ensuring it is fully seated.
  • Clean condenser and channel: Remove the condenser and rinse it. Clean the housing and water channel of lint and debris.
  • Inspect hoses: Access the lower front or rear to view condensate hoses. Tighten clamps and replace any cracked hoses.
  • Check sump and pump: Look for cracks or leaks around the sump and pump assembly. Replace faulty components if leaking.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condensate Hose
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements