Caple
Intermittent Power Supply / Loose Connections
Dryer display and lights flicker or reset during operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose mains plug or socket, Loose internal terminal block, Failing power supply components on PCB, Vibration causing intermittent connections
How to Fix / Troubleshooting
Safety first: Unplug the dryer before inspecting electrical connections.
- Check plug and socket: Ensure the plug fits firmly in the socket and there is no visible damage.
- Inspect terminal block: Tighten all screws on the mains terminal block and check for heat damage.
- Secure wiring harnesses: Ensure harnesses are clipped and not pulling on connectors due to vibration.
- PCB inspection: Look for cracked solder joints or loose connectors on the main PCB. Re-solder or replace the board if necessary.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Mains Terminal Block
Check Price on Amazon
We may earn a commission from links on this page.