Caple Moisture Sensor Under-Reading

Dryer display shows very short remaining times and ends the cycle quickly with clothes still wet, no error code.

Advertisements

Possible Causes

Sensor bars coated with fabric softener, Poor electrical contact to sensor, Drum not making good contact with laundry (very small loads), Faulty moisture sensor circuit

How to Fix / Troubleshooting

Safety first: Unplug the dryer before cleaning sensor bars or accessing wiring.

  • Thoroughly clean sensor bars: Use a non-abrasive pad and white vinegar to scrub the metal sensor strips inside the drum until shiny.
  • Avoid excessive softener: Reduce use of fabric softener sheets or liquids that can coat the sensors.
  • Use larger loads or timed cycles: For very small loads, use a timed program instead of automatic sensing.
  • Check sensor wiring: Inspect and test continuity from the bars to the PCB. Repair or replace if faulty.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Moisture Sensor Bars
Check Price on Amazon