Caple
Moisture Sensing / Control Logic Anomaly
Dryer runs but the time remaining display does not count down correctly or jumps unexpectedly.
Advertisements
Possible Causes
Dirty moisture sensor bars, Poor drum grounding, Firmware logic reacting to load size, Faulty moisture sensor circuit on PCB
How to Fix / Troubleshooting
Safety first: Unplug the dryer before cleaning sensor bars or accessing internal wiring.
- Clean moisture sensor bars: Wipe the metal strips inside the drum with a cloth and white vinegar to remove residues.
- Avoid small loads on auto programs: Very small loads can confuse moisture sensing. Use timed programs for small items.
- Check drum grounding: Ensure the drum is properly grounded via the bearing and grounding strap. Repair if loose or broken.
- Test moisture sensor wiring: Inspect and test continuity from sensor bars to PCB. Repair or replace harness if faulty.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Moisture Sensor Bars
Check Price on Amazon