E15
Caple Internal Overheat / Safety Thermostat Trip

Dryer shows E15 and may shut down unexpectedly; sometimes associated with internal overheating protection.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked internal air passages, Failed cooling fan (on heat pump models), Repeated tripping of safety thermostat, Faulty overheat sensor or wiring

How to Fix / Troubleshooting

Safety first: Turn off and unplug the dryer. Allow it to cool completely before working on it.

  • Clean all filters and condenser: Remove lint from the main filter and clean the condenser/heat exchanger thoroughly as per the user manual.
  • Inspect internal airflow: Remove panels to check for lint build-up around the heater, fan, and ducts. Vacuum out all debris.
  • Check cooling fan (if fitted): On heat pump models, ensure the cooling fan runs freely and is not obstructed. Replace the fan motor if seized or not running.
  • Reset manual thermostats: Some safety thermostats have a manual reset button. Locate on the heater housing or duct and press gently to reset if tripped. If it trips again, investigate the root cause of overheating.
  • Test thermostats and sensors: Use a multimeter to check continuity and resistance of overheat thermostats and sensors. Replace any faulty components with Caple-approved parts.